GENERATOR PROTECTION
Relays for the protection of synchronous and asynchronous generators
Performances of a generator can be affected by faults in the device as well as by outside perturbations on the supply network it is connected to.
CEE protections are designed to react as efficiently in the first and in the second case. They ensure protection for synchronous and asynchronous generators connected on three phase networks and moved by any type of machines: steam, hydraulic or gas turbine, diesel or gas engine.
Their protection functions and measurement functionalities make them appropriate for machine-generator groups from a few hundred kVA to tens of MVA.
Below the list of products dedicated to the protection of generators.
Device | Series | ANSI | Description | |
---|---|---|---|---|
NP G915 | NP.900 | 50/51, 50N/51N, 67, 67N, 50H/51H/68H, 46R/46L/46, 87N, 59, 27, 59P/27P/47, 59N, 81O/81U, 81R, 40, 51V, 64S, 32/37/32R, 49M, 21, 24, 78, 50BF/52BF, 60, 74TC, 25 | Enhanced generator protection IED with IEC 61850 protocol | |
NP T916 | NP 900 | 87T, 87N, 49T, 50/51, 50N/51N, 50H/51H/68H, 46R/46L/46, 50BF/52BF, 49L, 74TC, 86 | Differential protection IED with IEC 61850 protocol |
|
NPG800 | NP.800 | 21, 24, 27, 32, 37, 40, 46, 49, 50, 51, 50V, 51V, 59, 59N, 64, 81, 50BF, 74TC, 86 | Multi function generator protection | |
NPG800R | NP.800 R | 21, 24, 27, 32, 37, 40, 46, 49, 50, 51, 50V, 51V, 59, 59N, 64, 81, 50BF, 74TC, 86 | Multi function generator protection | |
NPW800 | NP.800 | 32, 37, 27, 59, 59N, 55, 81, 86, 74TC, BF | Multi function power, voltage and frequency protection | |
NPW800R | NP.800 R | 32, 37, 27, 59, 59N, 55, 81, 86, 74TC, BF | Multi function power, voltage and frequency protection | |
DMS 7001 | PROCOM | 87G | Digital differential protection relay | |
GMS 7001 | PROCOM | 49, 46, 40, 21, 51, 59, 24, 27, 81, 32, 59G (solo GMS, GMSV), 64 (solo GMSH) | Multi function generator protection | |
DTM 7033 | STATIC | 87G | Differential protection relay | |
FTT 7111 | STATIC | 24 | Overfluxing relay | |
HDG 7020 | STATIC | 81 | Over and under frequency relay | |
IAG 7034 | STATIC | 87 | Three phase high impedance differential protection | |
ITI 7521 | STATIC | 46 | Alternator negative sequence protective relay | |
ITV 7x66 | STATIC | 51V | Voltage restrained overcurrent protection | |
PTG 7000 | STATIC | 32, 37 | Over and under power protection | |
STEP 7000 | STATIC | 26 | Temperature supervision relay | |
TTE 7000 | STATIC | 64R | Rotor earth fault relay | |
TTGB 7031 | STATIC | 60 | Voltage balance relay | |
WTG 7000 | STATIC | 32P, 37P, 32Q, 37Q | Active or reactive power relay | |
YTM 7111 | STATIC | 40 | Loss of field relay |